EP Series Three-Phase Input Single-Phase Output Line Frequency Industrial UPS (10kVA to 30kVA)
Compact Online UPS With Output Isolation Transformer, N+1 Parallel Design For Small Industrial & IT Critical Loads
Product Overview
This EP series 3 phase input single phase output UPS adopts full digital control and pure online double conversion topology, supporting N+1 redundant parallel connection up to 6 units.
Equipped with built-in output isolation transformer, this EP series 3 phase input single phase output UPS suppresses mains surge, spike interference and load harmonic distortion, optimizing power matching between loads and UPS system. It delivers high reliability and availability for critical power protection, widely deployed for medium and small-scale key facilities including edge data rooms, communication cabinets, financial terminals, tunnel monitoring systems and semiconductor production lines.
Key Features & Benefits
Stable & Reliable Power Performance
● Wide input voltage and frequency tolerance reduces battery cycling and prolongs battery service life
● Integrated output isolation transformer minimizes neutral-ground voltage and harmonic disturbance to internal inverter
● Strong overload and short-circuit endurance protects equipment under harsh grid conditions
● Independent heat dissipation structure guarantees stable operation in tough installation environments
● True online double conversion architecture provides uninterrupted regulated power supply
Excellent Grid & Generator Compatibility
● Ultra-wide input voltage and frequency range adapts to unstable utility grid and diesel generator power supply
● Full DSP digital control improves overall system stability and dynamic response
User-Friendly Intelligent Operation
● Masterless autonomous current sharing parallel control, maximum 6 units for capacity expansion or redundancy
● Intuitive LCD panel for real-time status monitoring and local operation
● Optional RS232/RS485, SNMP and dry contact interfaces for remote centralized management
Universal Technical Specifications (All 4 Models Share These Parameters)
Main Input
Rated Input: 380Vac + N + PE three-phase
Input Voltage Range: 286-473Vac
Input Frequency Range: 50Hz±10%
Inrush Current: >20%
Bypass Section
Static Transfer Time: 0ms via static switch control
Bypass Overload Capacity: 200% load for 5 minutes; 1000% load for 10 seconds
Frequency Synchronization Range: ±1Hz, ±2Hz, ±3Hz adjustable
Manual Maintenance Bypass: Available
Battery Specification
Battery Type: Sealed lead-acid maintenance-free battery
DC Bus Voltage: 384Vdc
Battery Strings: 32 cells (29-32 cells optional)
Max Charging Current: 10A
Battery Deep Discharge Protection: Auto shutdown trigger
Output Performance
Nominal Output Voltage: 220Vac
Output Power Factor: 0.8
Voltage Regulation: ±1% for static load; ±2% for 100%-0% load step change
Battery Mode Frequency Stability: 50Hz±0.1%
THD: <1% linear full load; <3% 100% nonlinear load
Frequency Tracking Window: 46-54Hz
Output Waveform: Pure sine wave
Overload Characteristic: 125% load runs over 10 minutes; above 150% load transfers to bypass and shuts down after over 1 minute
Crest Factor: 3:1
Short-circuit Protection: Hardware auto-protection with bypass breaker trip
Inverter Fault Transfer: Automatic switchover protection
Topology: Online double conversion with built-in output isolation transformer
Full Load Efficiency: Above 90%
Environmental Conditions
Noise Level (2m front distance): <50dB
Operating Temperature: -10℃ to 40℃
Storage Temperature: -25℃ to 60℃ (battery excluded)
Relative Humidity: Below 95% non-condensing
Altitude Rating: No derating below 1000m
System Functions
N+1 Parallel Redundancy: Supported
Protection List: overload, short circuit, overtemperature, battery over/undervoltage
Cold DC Start: Supported
Generator Compatibility Mode: Supported
LCD Display Content: transformer status, rectifier status, inverter status, battery/bypass/alarm status, operation mode, electrical readings, historical fault log, language setting, ECO mode
Fan Control: Auto speed adjustment
Ingress Rating: IP20
Alarm Triggers: mains failure, battery abnormal voltage, overload, UPS fault, short circuit
Communication: Standard RS232 & USB; optional SNMP / dry contact terminals
Monitoring Software: Multi-OS supported, enables remote status check and remote shutdown
Model-Specific Dimension & Weight Table
| Model | Rated Capacity | Dimension(W×D×H, mm) | Net Weight(kg) |
|---|---|---|---|
| EPSD010L | 10kVA/8kW | 310×670×820 | 74 |
| EPSD015L | 15kVA/12kW | 310×670×820 | 99 |
| EPSD020L | 20kVA/16kW | 310×670×820 | 117 |
| EPSD030L | 30kVA/24kW | 310×670×820 | 125 |
Typical Application Scenarios
1.Edge data centers and communication server rooms
2.Financial service branches, securities trading and bank data terminals
3.Highway / railway tunnel lighting and monitoring control rooms
4.Port information centers and urban stadium control systems
5.Semiconductor manufacturing lines and factory automated production control nodes
Frequently Asked Questions
Q1: How many units of this EP series 3 phase input single phase output UPS can be paralleled?
A1: The masterless parallel architecture allows up to 6 units for N+1 redundancy or capacity expansion.
Q2: Can this UPS work with diesel generator power supply?
A2: Yes, wide frequency and voltage input range is optimized for generator fluctuating output.
Q3: What is the advantage of built-in output isolation transformer?
A3: It suppresses surge noise, reduces neutral-ground voltage and lowers load harmonic feedback to upstream grid.
Q4: Does the unit support maintenance bypass operation?
A4: Manual maintenance bypass is equipped for hot servicing without powering down critical loads.
Q5: What is the derating rule for high altitude installation?
A5: Full power output can be achieved below 1000m altitude, capacity derating is required above this height.
Quality & Compliance
This line frequency UPS adopts industrial-grade redundant component design, all performance indicators are verified under standardized factory testing for long-term stable operation at commercial and light industrial sites.