UPSBOSS delivers the HGU-XE48 series as the most compact, telecom-grade DC-to-AC inverter UPS for 48 V battery plants. Four capacity steps — 3 kVA, 5 kVA, 8 kVA and 10 kVA — share one 1U/2U rack chassis that drops straight into a standard 19-inch cabinet, takes its DC feed from any -48 V telecom plant or solar battery bank, and returns clean 220 V pure sine wave power to your AC load with ≤5 ms static-bypass handover.

Built around a high-frequency SPWM CPU-controlled inverter with bidirectional AC/DC priority logic, the HGU-XE48 keeps communication sites, edge cabinets and remote industrial nodes alive through grid failure, generator switchover and long utility outages — without the noise, weight or footprint of a traditional AC-input double-conversion system.
Engineered for unattended operation in telecom base stations, solar / wind hybrid plants, railway signalling rooms, marine vessels and emergency response vehicles, every HGU-XE48 unit ships with CE, TUV, IEC 62040, ISO 9001 and RoHS compliance, and is backed by UPSBOSS's global 3-year warranty and 24/7 multilingual engineering support.
The HGU-XE48 is a 1U/2U 19-inch rack-mount pure sine wave inverter that bridges the 48 V DC battery world and the 220 V AC load world. Where conventional AC-input UPS units only protect against grid disturbances, the HGU-XE48 is purpose-built for sites where the primary energy source is already DC — telecom DC plants, off-grid PV battery banks, hybrid wind/solar systems and mobile DC platforms.
At the heart of the unit, a high-frequency SPWM control loop running on an industrial-grade CPU produces a clean sine wave with ≤3% THD on linear load, adaptive 50/60 Hz output, and voltage stability within ±15%. An integrated static AC bypass switch hands the load over to utility mains in ≤5 ms whenever mains is present and healthy, so mission-critical AC equipment never sees a glitch — even during deep battery cycling or generator changeover.
The platform is modular by design: any combination of 3 kVA, 5 kVA, 8 kVA and 10 kVA modules can be paralleled across racks to scale capacity in 2.4 kW to 7 kW building blocks. The result is a pay-as-you-grow power architecture for small-cell sites, PoP rooms, remote oil & gas telemetry, marine electronics rooms and emergency backup cabinets — all from one unified inverter family.
If your site runs on AC mains and you need a modular online double-conversion UPS for an IT room, see the HPM Modular UPS family. If your site already has a -48 V DC battery plant and you need 220V AC for telecom, solar, marine or industrial loads, the HGU-XE48 below is the right platform.
| Item | Technical Specification |
|---|---|
| Series | HGU-XE48 — 1U/2U rack-mount telecom inverter UPS |
| Capacity range | 3 kVA / 5 kVA / 8 kVA / 10 kVA (single module) |
| Topology | High-frequency SPWM, CPU-controlled, with static AC bypass |
| DC input | 48 Vdc nominal (operating range 45.5 – 57 Vdc) |
| AC bypass input | 220 Vac, 50 Hz, 187 – 238 V tolerance |
| AC output | 220 Vac ±15% pure sine wave (110 V optional), 50/60 Hz adaptive |
| Output frequency | 50 Hz ±0.1% / 60 Hz ±0.1% (auto-sensing) |
| Output THD | ≤3% linear load / ≤5% non-linear load |
| Power factor | 0.8 lagging (0.7 selectable) |
| Inverter efficiency | ≥85% (DC → AC, typical load) |
| Bypass transfer time | ≤5 ms (typical <3 ms) |
| Operating temperature | -20 °C to +50 °C |
| Noise (1 m) | ≤40 dB |
| Cooling | Forced-air, intelligent variable-speed fan |
| Protection | Over-voltage, under-voltage, overload, short-circuit, over-temperature, surge, reverse-polarity |
| Communication | RS-485, RS-232, optional SNMP / Web card slot |
| Display | LCD + status LEDs, front-panel access |
| Certifications | CE, TUV, IEC 62040, ISO 9001, ISO 14001, RoHS |
| Warranty | 3-year full unit, global support |
DC Input
AC Bypass Input
AC Output
Protection Functions
Environmental & Communication
| Model | Rated Power | Output Power | DC Input Current | AC Output Current | Chassis (D × W × H, mm) | Weight (kg, approx.) |
|---|---|---|---|---|---|---|
| HGU-XE48-3K | 3 kVA | 2.4 kW | 63 A | 10.8 A | 440 × 482 × 88 | ~16 |
| HGU-XE48-5K | 5 kVA | 3.5 kW | 100 A | 16 A | 440 × 482 × 88 | ~16 |
| HGU-XE48-8K | 8 kVA | 5.5 kW | 167 A | 25.4 A | 440 × 482 × 176 | ~28 |
| HGU-XE48-10K | 10 kVA | 7 kW | 210 A | 31.8 A | 440 × 482 × 176 | ~28 |
Compatible Energy Storage & Power Chain
Telecom-Site Integrated Power Solution
Pair the HGU-XE48 inverter UPS with HGU-Series -48 V batteries, PV Generator hybrid solar cabinet and SLT distribution to deliver a complete DC-input AC-output power chain for off-grid and bad-grid telecom sites — single-vendor sourcing from UPSBOSS, one warranty, one support hotline.
Q1. How is the HGU-XE48 different from a conventional online UPS?
The HGU-XE48 is a DC-to-AC inverter UPS, purpose-built for sites where the primary energy source is already 48 V DC (telecom plants, solar / wind battery banks, mobile platforms). It accepts a -48 V DC feed directly, converts it to clean 220 V pure sine wave, and adds a ≤5 ms static AC bypass for grid continuity — eliminating the AC rectifier stage of a conventional UPS and saving significant rack space. For AC-input IT-room applications, consider the HPM Modular UPS family instead.
Q2. Can the HGU-XE48 work directly with solar panels and lithium batteries?
Yes. The HGU-XE48 connects to the 48 V battery bank of any 48 V solar / wind hybrid system, including those with MPPT charge controllers, lithium battery management systems (BMS) and lead-acid strings. It runs from any 45.5 – 57 V DC source with stable voltage. For an end-to-end off-grid PV solution, pair the inverter with UPSBOSS PV Generator series.
Q3. What battery bank do you recommend?
Size the battery bank in amp-hours at the 48 V DC input current rating — for example, 63 A continuous for the 3 kVA model. UPSBOSS HGU-Series VRLA and HGU-HVC lithium batteries are pre-validated for the HGU-XE48 and ship with matched DC cables and breakers.
Q4. Can I parallel HGU-XE48 modules for higher capacity?
Yes. Up to four HGU-XE48 modules of mixed capacity (e.g. 3K + 5K + 8K + 10K) can be paralleled in N+1 redundant configuration to build non-equal-capacity strings from 3 kVA up to 40 kVA. Contact UPSBOSS engineering for the parallel-kit datasheet and commissioning guide.
Q5. How fast is the AC-bypass transfer?
Static transfer time is ≤5 ms (typical <3 ms), well inside the ride-through window of IT equipment, telecom baseband units and industrial PLCs. Most sensitive loads will not register an event.
Q6. Is the LCD interface bilingual and easy to use in the field?
Yes. The LCD supports English and Chinese with parameter query, fault history, output-voltage adjustment and battery-test functions. Status LEDs on the front panel give an at-a-glance health check for tower-top and remote-cabinet service.
Q7. What global certifications does the HGU-XE48 carry?
CE, TUV, IEC 62040, ISO 9001, ISO 14001 and RoHS, plus country-specific marks on request. The product is qualified for export to North America, the EU, the GCC, Africa and most Asia-Pacific markets.
Q8. What warranty and after-sales support do you offer?
3-year full-unit warranty, optional 5-year extended coverage, with global regional spares, factory-trained local engineers and 24/7 multilingual technical support. OEM / ODM branding, colour and firmware customization are available for volume orders.
Downloadable Resources
Global After-Sales Guarantee
UPSBOSS delivers the HGU-XE48 with global logistics and field-service coverage: regional spares warehouses, factory-trained local engineers, 24/7 multilingual technical support hotline and predictable preventive-maintenance schedules. OEM / ODM services and custom firmware / branding are available for qualified partners and volume orders. Contact UPSBOSS engineering for sizing, parallel configuration, battery matching and project quotation.
Talk to UPSBOSS engineers about sizing, redundancy and local compliance for your site.