Welcome to HG Group official website – your trusted supplier of data center power solutions
PRODUCTS

High-Frequency Tower UPS

EP-KL Series 3P3P High Frequency Tower UPS 10

  • Model: EP-KL10-200L
  • Specification: 10/15/20/30/40/60/80/100/120/160/200kVA
  • Size: 250×720×535mm-530×890×1300mm
  • Weight: 33.2-221Kg
  • Description: EP-KL three-phase input three-phase output high frequency tower UPS covers 10/15/20/30/40/60/80/100/120/160/200kVA models. 10-60kVA adopts 7-inch color touch LCD, 80kVA and above is equipped with 10.4-inch industrial touch screen. Input voltage 138-485Vac, output PF 0.9, overall efficiency ≥95%, graded noise from ≤55dB to ≤65dB. Compact tower structure with actual size and weight strictly following YD/T 1095-2018 standard, full CE/TUV/IEC certification. Suitable for branch computer rooms, small factories, commercial buildings, clinics and campus backup power, support global project bidding and OEM/ODM customization.
  • Online ordering

EP-KL Series 3P3P High Frequency Standalone Tower UPS (10kVA ~ 200kVA)

Product Positioning: Compact graded tower UPS for branch computer rooms, small factories, commercial and medical education power scenarios

Full Model List: EP-KL010L / EP-KL015L / EP-KL020L / EP-KL030L / EP-KL040L / EP-KL060L / EP-KL080L / EP-KL100L / EP-KL120L / EP-KL160L / EP-KL200L

Screen Rule: 10~60kVA → 7" Color Touch LCD; 80~200kVA → 10.4" Industrial Anti-Glare Touch LCD

Executive Standard: YD/T 1095-2018


1. Product Overview

      Different from heavy large-capacity tower UPS, the EP-KL 10-200kVA series adopts graded compact cabinet design, cabinet dimension, weight, noise and charging current are set by power segment strictly in line with official technical specification. It adopts full digital high-frequency double conversion architecture, with 138~485Vac ultra-wide input voltage range, strong adaptability to fluctuating mains and diesel generator sets.

      The series is equipped with two sizes of touch screens to balance cost and operation demands: small and medium power 10-60kVA uses 7-inch color touch screen for daily parameter checking and fault alarm; 80-200kVA high-power models upgrade to 10.4-inch industrial touch screen with complete log storage and waveform query functions. Rich communication ports including RS485, CAN, Ethernet are reserved, SNMP card can be added for remote centralized monitoring.

      Multi-unit parallel redundant operation is supported to build N+1/N+X backup system. The fan speed is controlled by temperature linkage, so the noise is controlled in different ranges by capacity, perfectly adapting to office, clinic, factory workshop and other environments with different noise requirements.


2. Core Product Advantages

2.1 Graded Compact Cabinet, Reasonable Space Matching

   ● Four groups of standardized cabinet dimensions are designed for different power ranges, avoiding excessive space occupation of small-capacity models, and meeting heat dissipation demand of large-capacity models.

   ● Light weight for small models, easy for single-unit handling and installation; medium and large models adopt reinforced cabinet structure to ensure stable operation under long-time full load.

   ● Internal wiring is standardized and partitioned, convenient for on-site construction and later circuit maintenance.

2.2 Dual-Size Touch Screen, Cost-Optimized O&M Configuration

   ● 10~60kVA: 7-inch color touch LCD, covers real-time electrical data display, fault prompt and local parameter setting, cost advantage for small commercial projects;

   ● 80~200kVA: 10.4-inch industrial touch screen, adds operation log storage and fault waveform recording functions, suitable for refined management of branch computer rooms and medium factories.

2.3 Stable Power Quality, Strict Communication Industry Standard

   ● Input current THDi ≤4% under linear load, ≤5% under non-linear load, effectively filtering grid harmonic interference; output voltage regulation accuracy reaches ±1%, voltage THD ≤2% for linear load, ≤4% for non-linear load.

   ● Output power factor 0.9, matching mainstream server and industrial load characteristics; overall machine efficiency ≥95%, reducing daily operating power consumption.

   ● Battery voltage ranges ±180V~±300Vdc, battery sections 30~50 adjustable, flexible for different backup duration demands.

2.4 Graded Noise Control, Adapt to Multiple Scenarios

   ● 10-30kVA noise ≤55dB, suitable for quiet office and medical places;

   ● 40-60kVA noise ≤58dB, fit for small equipment rooms and retail stores;

   ● 80-120kVA noise ≤60dB, applicable to general factory workshops;

   ● 160-200kVA noise ≤65dB, for independent machine room scenarios.

2.5 Complete Protection & Rich Extended Communication

   ● Full protection: battery under-voltage, output over-voltage, short circuit, overload, over temperature, fan fault alarm;

   ● Standard interfaces: CAN, RS485, FE, parallel card; SNMP monitoring card optional for DCIM platform docking;

   ● Pass global safety certifications, fully comply with YD/T 1095-2018 telecommunication UPS standard, support domestic and foreign project bidding.


3. Typical Application Scenarios

     1.Enterprise branch computer rooms, campus network equipment rooms, community weak current machine rooms

     2.Small and medium processing workshops, laboratory precision testing equipment

     3.Shopping malls, chain stores, office building power distribution systems

     4.Community clinics, medical institutions, small medical imaging equipment

     5.Municipal intelligent terminals, highway toll stations, edge computing nodes


4. Full Series Parameter Comparison Table (Strictly from Manual)

ModelRated CapacityDisplayCabinet Size W×D×H(mm)Net Weight(kg)1m NoiseMax Charging CurrentOnline Efficiency
EP-KL010L10kVA/9kW7" Color Touch LCD250×720×53533.2≤55dB5A≥95%
EP-KL015L15kVA/13.5kW7" Color Touch LCD250×720×53533.6≤55dB5A≥95%
EP-KL020L20kVA/18kW7" Color Touch LCD250×720×53534.1≤55dB10A≥95%
EP-KL030L30kVA/27kW7" Color Touch LCD250×720×53535.2≤55dB10A≥95%
EP-KL040L40kVA/36kW7" Color Touch LCD250×868×85240.2≤58dB15A≥95%
EP-KL060L60kVA/54kW7" Color Touch LCD250×868×85270.5≤58dB15A≥95%
EP-KL080L80kVA/72kW10.4" Industrial Touch LCD440×885×1200141≤60dB20A≥95%
EP-KL100L100kVA/90kW10.4" Industrial Touch LCD440×885×1200161≤60dB20A≥95%
EP-KL120L120kVA/108kW10.4" Industrial Touch LCD440×885×1200163≤60dB30A≥95%
EP-KL160L160kVA/144kW10.4" Industrial Touch LCD530×890×1300194≤65dB30A≥95%
EP-KL200L200kVA/180kW10.4" Industrial Touch LCD530×890×1300221≤65dB40A≥95%


4.1 Universal Electrical Parameters (Manual Original Data)

Input

   ● Wiring: 3 Phase 5 Wire (3P+N+PE), rated voltage 380/400/415Vac

   ● Input voltage range: 138~485Vac

   ● Frequency range: 50/60Hz±5Hz

   ● Input power factor ≥0.99

   ● Input current THDi: ≤4% (linear load), ≤5% (non-linear load)

   ● Generator input supportable

Output

   ● Wiring: 3 Phase 5 Wire, rated voltage 380/400/415Vac

   ● Output power factor: 0.9

   ● Voltage regulation accuracy: ±1%

   ● Output frequency: Mains mode ±1%/±2%/±4%/±5%/±10% adjustable; battery mode (50/60±0.1)Hz

   ● Crest factor: 3:1

   ● Voltage THD: ≤2% (linear load), ≤4% (non-linear load)

   ● Overload capacity: 110% long-term running; 125% lasts 10min; 150% lasts 1min

Battery

   ● DC voltage: ±180V~±300Vdc (30~50 cells adjustable)

   ● Max charging current: graded as table above

Environment

   ● Operating temperature: 0℃~40℃

   ● Storage temperature: -25℃~55℃

   ● Humidity: 0~95% non-condensing

   ● Max full-load altitude: ≤1500m

Communication & Protection

   ● Alarms for overload, mains abnormality, UPS fault, battery under-voltage

   ● Protection: battery under-voltage, output over-voltage, short circuit, overload, over temperature, fan fault alarm

   ● Ports: CAN, RS485, FE, parallel card; SNMP card optional


5. Matching Solutions & Global Custom Service

Supporting Equipment

     1.Matched valve-regulated lead-acid battery packs

     2.High-voltage lithium iron phosphate energy storage cabinet

     3.Small precision air conditioner for branch machine rooms

     4.ATS dual power automatic switching cabinet

     5.Lightweight DCIM remote monitoring platform

Customization Service

     Support voltage parameter adjustment, multi-language screen firmware, customized charging current, cabinet anti-corrosion treatment. Provide overseas technical guidance, parallel debugging and personnel training, OEM/ODM private label service for global distributors.


6. FAQ

Q1: What is the difference between EP-KL and heavy EPKL 300-800kVA UPS?

A1: EP-KL is graded compact cabinet for medium-small loads, with segmented dimension, weight and noise, complying with YD/T 1095 communication standard; EPKL 300-800kVA is heavy reinforced tower for large IDC and heavy industry.

Q2: Why adopt two sizes of touch screens?

A2: 7-inch screen controls cost for 10-60kVA small projects; 10.4-inch industrial screen adds log and waveform functions for medium-large capacity models.

Q3: Can multiple units run in parallel?

A3: Yes, parallel function is standard, build N+1 redundant system for load expansion.

Q4: Is the noise suitable for office scenarios?

A4: 10-30kVA noise ≤55dB, fully meets quiet office and medical environment requirements.

Q5: Does it meet export certification requirements?

A5: It complies with YD/T 1095 and international CE/TUV/IEC standards, complete test reports for global project bidding.


7. Document Download & After-Sales

Download Files

   ● EP-KL 10-200kVA English datasheet (YD/T1095 version)

   ● Installation & parallel operation manual

   ● Full certification documents

Warranty

   ● 3-year global whole machine warranty, key power components 5-year warranty

   ● 24/7 multilingual remote technical support

   ● Local agent on-site maintenance & OEM customization available