P-Class Single Row Multi-Cabinet Micro Modular Data Center
1. Product Overview
Our P-Class multi-cabinet micro modular data center centralizes all hardware required for small and medium data centers inside fully enclosed hot and cold aisle cabinets, paired with comprehensive environmental sensors and centralized dynamic environment monitoring platform. It condenses complete data center infrastructure into a compact footprint, delivers stable operating conditions for IT equipment and elevates remote intelligent management capabilities, cutting on-site professional engineering maintenance work and simplifying overall project construction & daily operation workflows.
This series supports 3 to 9 units of 42U cabinets in a single row, powered by 380Vac, 50Hz 3Ph+N+PE grid standard. Its operating ambient temperature ranges from 0-40℃ with humidity adaptability of 5%-95%. The system works reliably at altitude 0-4000m, and power derating is mandatory for deployment above 1000m. The product is certified with 3C and TEL certificates to satisfy global project compliance requirements.
Single cabinet dimension is 600×1200×2000mm, the whole row consists of control cabinet, IT racks and optional battery cabinets with dual hot & cold aisle containment design. For a configuration with N total cabinets, available IT installation space equals 42U×(N-1), the exact usable capacity varies based on final layout design. Main input breaker ranges from 63A to 125A, while power output circuits can be fully customized according to client project demands.
The built-in UPS capacity covers 6kVA to 30kVA: 6-10kVA adopts standalone single UPS configuration, and 20-30kVA supports dual redundant UPS setup. UPS power factor reaches 1 with peak operating efficiency up to 97%. Vertically mounted national standard PDU is preinstalled, equipped with socket layout of 16×10A plus 4×16A GB outlets.
Backup power adopts 9AH battery packs, with installable quantity from 0 to 4 packs. Users can select battery pack, battery rack or dedicated battery cabinet for backup deployment, adjustable backup runtime falls between 15 minutes and 4 hours.
Local management is realized via 10-inch touchscreen monitoring all-in-one unit. Standard onboard configurations include status indicator light, water leakage detector, temperature & humidity sensor, door contact sensor and smoke detector; SMS alarm notification is provided as an optional upgrade. Matched precision cooling unit offers 12.5kW cooling capacity, available in rack-mounted variable frequency or row-level type running at 380V, while auxiliary heat dissipation component works at 220V with 3kW rated heat load.
2. Application Scenarios
This multi-cabinet micro modular data center fits medium-scale IT infrastructure construction across mainstream industries:
● Government agencies and municipal data branches
● Regional financial headquarters and banking data sub-centers
● Large commercial complexes and industrial parks
● Hospital information centers and medical data hubs
● University campus data labs and education research centers
● Manufacturing industrial control centers and factory server rooms
3. Core Product Advantages
3.1 Stable & Reliable Operation
All components are manufactured complying with both domestic and international quality standards. Full factory prefabrication, pre-assembly and pre-commissioning strictly control every procedure to eliminate on-site installation risks. Integrated architecture improves overall system reliability, intelligent spring door structure guarantees continuous equipment running, and full redundancy design paired with real-time intelligent monitoring prevents unexpected downtime for your multi-cabinet micro modular data center.
3.2 Fast Onsite Deployment
The solution minimizes traditional civil engineering work to adapt diverse deployment sites. Plug-and-play modular design streamlines installation and maintenance, total on-site commissioning only takes 4-6 hours. It integrates refrigeration, power distribution, UPS, battery, monitoring and cabling inside one row, and supports elastic capacity expansion up to 16 connected cabinets.
3.3 High Energy Saving Performance
Near-precision cooling via row or rack air conditioners greatly improves heat exchange efficiency, delivering over 25% energy saving compared with conventional data rooms. N+X online modular UPS supports intelligent sleep mode to cut idle power consumption. Remote unmanned operation lowers long-term TCO, and sealed hot/cold aisle forms internal airflow circulation to optimize cooling efficiency and reduce recurring operational costs.
4. Packaging & Weight Reference
● Single unit outer packaging dimension: 734×1360×2200mm
● Net weight: 142kg per standard cabinet, 100kg per dedicated IT cabinet
● Single battery pack weight: 48kg
5. Why Choose Our P-Class Multi-Cabinet Micro Modular Solution
1.Highly scalable row architecture: Start from 3 cabinets and expand stepwise up to 16 cabinets, avoiding excessive upfront investment for growing IT workload.
2.Factory pre-integration: Core subsystems are fully assembled and tested before delivery, drastically shortening project lead time and on-site engineering workload.
3.Outstanding energy optimization: Aisle containment + high-efficiency modular UPS jointly reduce long-term electricity expense, bringing visible TCO reduction for medium data centers.
4.Low manpower operation: Centralized remote monitoring supports unmanned site management, cutting annual on-site maintenance labor cost significantly.
5.Broad environment adaptability: Suitable for regional branch data hubs, industrial control rooms and unattended edge medium data centers across different climate zones.
6. Frequently Asked Questions (FAQ)
Q1: What is the maximum expandable cabinet quantity for this micro modular data center?
A1: Standard base configuration ranges 3-9 cabinets per row, the system can be further extended to maximum 16 cabinets placed in line for future capacity upgrade.
Q2: How much energy saving can I get compared with a traditional built-to-suit data room?
A2: With hot/cold aisle containment and high-efficiency modular UPS, overall power consumption can be reduced by more than 25% against conventional non-containment server rooms.
Q3: Can I customize UPS redundancy and output circuit layout?
A3: Yes. 6-10kVA uses single UPS by default while 20-30kVA supports dual UPS redundancy; all output distribution circuits can be tailored to your terminal IT load requirements.
Q4: Is high-altitude deployment supported for this row containment solution?
A4: It supports 0-4000m deployment. Power derating is required when site altitude exceeds 1000m, please inform our sales team of exact altitude during inquiry.
Q5: Can I select between rack-mounted AC and row-level cooling?
A5: Both 12.5kW rack variable frequency AC and row-level precision AC are optional, you can confirm cooling type based on your on-site airflow planning.
7. Inquiry & Customization CTA
If you need customized cabinet quantity, UPS capacity, backup duration or cooling configuration for this integrated multi-cabinet micro modular data center, submit your project scale, local grid specification, site altitude and load demand. Our technical and commercial team will send you customized quotation and layout design within 24 working hours.
For medium-sized scalable edge data infrastructure with balanced reliability, energy efficiency and deployment flexibility, our P-Class row micro modular solution is a proven cost-effective option for global enterprise data center projects.