Intelligent rack PDU — Ethernet / RS485, remote monitoring, control, threshold & alarms for data centers.
S-Smart PDU is the next-generation intelligent power-distribution management device for data-center network-cabinet terminal power distribution. Through Ethernet, RS485 and other mature communication means, S-Smart PDU upgrades traditional PDUs with intelligent remote monitoring, control and management of end-device power.
Working temperature: −5 °C ~ +60 °C
Working relative humidity: ≤ 90 % (40 °C ± 2 °C), ≤ 95 % non-condensing
Altitude: ≤ 2 000 m
Storage temperature: −40 °C ~ +70 °C
Storage relative humidity: ≤ 95 % (40 °C ± 2 °C)
Total load current (A)
Working voltage (V)
Total power (kW)
Frequency (Hz)
Per-circuit load current (A)
Temperature, humidity, smoke, water leakage (separate module required)
Main power on / off
Per-circuit power on / off
Per-circuit scheduled on / off
Per-circuit timed on / off
Total current upper limit
Voltage upper / lower limit
Per-circuit current upper / lower limit
Temperature upper / lower limit
Total power overrun alarm
Temperature / humidity overrun alarm
Smoke alarm
Water-leakage alarm
Communication: Ethernet, RS485
Monitoring: total current / voltage / power / frequency, per-circuit current, environmental sensors (separate modules)
Control: main and per-circuit on/off, scheduled and timed
Thresholds: total current, voltage, per-circuit current, temperature
Alarms: power overrun, temperature / humidity overrun, smoke, water leakage
Use case: data-center network-cabinet terminal power distribution
One dashboard for every outlet — per-circuit current monitoring and control let you manage every device in the rack from a single console.
Predictive alarms — total power, temperature, humidity, smoke and water-leakage thresholds surface issues before downtime.
Open standard protocols — Ethernet and RS485 integrate with mainstream DCIM, BMS and UPS monitoring platforms.
Reduce on-site visits — remote on/off, scheduled and timed control cut truck-rolls for after-hours power cycling.
Wide environmental envelope — working temperature −5 °C ~ +60 °C, altitude ≤ 2 000 m, suitable for most global data-center sites.
Modular environmental sensing — separate temperature, humidity, smoke and water-leakage modules scale to your site risk profile.
How does S-Smart PDU communicate with the data center?
Through standard Ethernet and RS485 interfaces, integrating with mainstream DCIM, BMS and UPS monitoring platforms.
Can S-Smart PDU control individual outlets?
Yes — per-circuit power on/off, scheduled on/off and timed on/off are all supported.
Does S-Smart PDU support environmental monitoring?
Yes — separate modules support temperature, humidity, smoke and water-leakage sensing with their own overrun alarms.
This page cannot submit forms directly. Please go to our FEEDBACK page and our technical sales team will reply within 1 working day with a customized distribution scheme and formal quotation.
Prepare before submitting:
Your full name & company name
Project country & exact location
Project type: data center network cabinet / edge site / colocation rack
Total rack load & number of circuits required
Required communication (Ethernet / RS485 / both)
Environmental modules needed (temperature / humidity / smoke / water leakage)
Integration target (DCIM / BMS / UPS monitoring)
All project information is strictly confidential.
Complete LV power distribution ecosystem — 8 product families from main switchgear to terminal PDU
SDCT — new generation intelligent LV switchgear assembly (up to 6300 A)
SDB — drawer-type LV switchgear (up to 4000 A)
SDG — fixed-type LV switchgear (up to 1600 A)
SDS — power distribution cabinet & box (up to 630 A / SDSF 400 A)
SJMP — precision power distribution cabinet
MASTER-LINE — data center busway system
S-PDU — standard rack power distribution unit
S-Smart PDU — intelligent rack power distribution unit
International and Chinese national standards compliance for global export qualification
Standard communication interfaces for UPS, cooling and environment-monitoring integration
Responsive technical sales team — detailed proposal within 1 working day
© HG Group upsboss · Privacy Policy · Contact · Compliance
Contact: Frank Zhang
Phone: +86-135 5688 8641
Email: frank@upsboss.com
Add: Jufeng Road, Guangming Street, Guangming District, Shenzhen City, Guangdong Province, China
We chat